                              | ETRAP 
                                200523 - 25 November in Brussels, Belgium 3rd International Conference on Education and Training in   Radiological Protection
                                  
                                    | Title  |   | Towards a specific education and training programme in radiological protection for practitioners in interventional cardiology  |  
                                    | Presented by  |   | Thierens, Hubert  |  
                                    | Institute(s)  |   | Ghent University, Radiological Protection Department (BE)  |  
                                    | Description  |   | Authors: H.  Thierens  (1,2),  E.  Bogaert  (2),  K.  Lemmens  (2),  K.  Bacher  (2)
 
 Full  affiliation:
 (1)  Radiological  Protection  Department
 (2)  Medical  Physics  Department  University  Ghent,  Proeftuinstraat  86,  B-9000  Ghent,  Belgium
 
 Abstract:
 With  respect  to  exposures  in  the  medical  sector,  doses  to  patients  and  practitioners  are  among  the  highest  in  interventional  cardiology.  The  ongoing  FANC  study  in  Belgium  shows  that  in  case  of  difficult  interventions  skin  doses  in  patients  exceed  frequently  the  threshold  for  direct  effects  of  2  Gy.  Appropriate  education  and  training  in  radiological  protection  for  practitioners  in  interventional  cardiology  is  an  urgent  need  to  keep  doses  at  an  acceptable  level.
 
 Apart  from  general  radiological  protection  issues  applicable  to  all  medical  uses  of  X-rays,  education  and  training  programmes  of  cardiologists  and  other  practitioners  in  the  catheterization  laboratory  should  deal  with  the  specific  measures  to  be  taken  to  reduce  patient  and  personnel  doses  when  using  C-arm  X-ray  equipment  in  fluoroscopy  and  cine  mode.
 Based  on  the  data  of  the  FANC  multicenter  study  in  Belgium  a  number  of  important  recommendations  for  this  specific  interventional  cardiology  section  in  radiological  protection  programmes  will  be  given.  Monte  Carlo  simulations  of  patient-X-ray  equipment  geometries  will  be  used  to  demonstrate  the  impact  of  the  different  variables  and  changes  of  procedures  on  patient  and  practitioner  doses.    The  use  of  the  DAP-reading  as  on-line  patient  dose  indicator  will  be  discussed.
 
 |  
                                    | Full paper  |   | Thierens.pdf   (31 KB - 31,472 bytes) |  
                                    | Presentation  |   | Thierens.pdf   (43 KB - 43,933 bytes) |  
                                    | << back |  |  |  
 |  |